Test nitrogen gas dew point if can be reach -40℃
Judgment Standard: Qualified if atmospheric pressure dew point ≤ -40℃
The dew point of nitrogen indicates the water vapor content in nitrogen: the lower the dew point temperature, the less moisture there is. A dew point of -40°C is the general industrial threshold for dry nitrogen. Excessive moisture will directly lead to product scrapping, equipment damage, process failures and potential safety hazards.
Sep 9th,2026
10 الآراء
Use Portable Capacitance Dew Point Meter (For On-site Rapid Inspection)
Handheld and portable, with a measuring range of -70 to +20°C and an accuracy of ±1 to ±2°C, suitable for quick on-site judgment. If the reading falls within the range of -38 to -42°C, it can be approximately regarded as meeting the -40 grade standard.
Why does the industry commonly target a dew point of -40°C?
At atmospheric pressure, a dew point of -40°C corresponds to a water vapor content of approximately 124 ppm, marking the cost-performance balance point:
Above -40°C (e.g., -30°C, -35°C): Excess moisture leads to oxidation and defects in most precision processes;
≤ -40°C: Meets basic moisture and oxidation prevention requirements for the vast majority of welding, electronics, heat treatment and packaging processes;
For ultra-precise processes (semiconductors, lithium battery vacuum coating), the dew point needs to be further reduced to -60°C or lower